Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.8710232

- Product Categories
- Friendly Links
- home > Supply > The supply of petrochemical liquid turbine flowmeter, liquid turbine supply 18,637,313,237
Information Name: | The supply of petrochemical liquid turbine flowmeter, liquid turbine supply 18,637,313,237 |
Published: | 2012-05-29 |
Validity: | 90 |
Specifications: | No |
Quantity: | 1.00 |
Price Description: | |
Detailed Product Description: | Henan Airlines Traffic Instrument Co., Ltd. the XFE Series Liquid Turbine flowmeter About The XFT Series turbine flow meter works When the measured fluid flow through the sensor in the fluid under the action of the impeller rotation by force, its speed and pipeline average velocity is proportional to the impeller rotation cycle to change the magnetic reluctance of the converter value. Flux followed by cyclical changes in the detection coil, resulting in periodic EMF electrical pulse signal by the amplifier, and sent to the instrument display. Practical turbine flowmeter flow equation qv = f / K qm = qvρ Where qv, qm-for volume flow, m3 / s, the mass flow rate, kg / s; f-flow meter output signal frequency, Hz; K-flow meter, the meter factor P/m3. The meter factor can be divided into Sec linear segment and non-linear segment. The linear section is about two-thirds of the working section, its characteristics and structure of the sensor size and fluid viscosity. Nonlinear segment, features bearing friction, fluid viscous resistance greater impact. When the flow is lower than the sensor flow limit, the meter factor is rapidly changing with the flow. Pressure loss and flow rate is approximately the square of. When the flow exceeds the flow limit to prevent cavitation. The structure is similar to the shape of the curve of the turbine flowmeter features are similar, he only differ in the level of systematic errors. The XFT series main features of the turbine flowmeter 1) High accuracy for liquids are generally ± 0.25% of the R-± 0.5% R, high-precision up to ± 0.15% R; medium is gas, generally ± 1.5% ± 1% of the R-R, the special type of ± 0.5% R-± 1% R. In all flow meter, it belongs to the most accurate. 2) Good repeatability, short-term repeatability of up to 0.05% -0.2%, good reproducibility, such as the regular calibration or online calibration can be very high accuracy, in the trade settlement is the preferred flow meter. 3) The output pulse frequency signal, suitable for the measurement of total and computer connection, no zero drift, strong anti-interference ability. 4) Availability of high frequency signals (3-4kHz) signal resolution and strong. 5) Range is wide, medium and large caliber up to 40:1-10:1, small-diameter is 6:1 or 5:1. 6) The compact and lightweight, convenient installation and maintenance, flow capacity. 7) Suitable for high pressure measurements on the body of the instrument table without opening, easily made from high-pressure instrument. 8) Specific sensor types can be designed in accordance with the special needs of the users of all kinds of special sensors, such as low temperature, two-way, underground type, sand-specific type. 9) The insertion can be made suitable for large diameter measurement, pressure loss, low prices, from time to drying out, easy installation and maintenance. 10) Liquid Turbine flowmeter does not apply to the higher viscosity media (except for the high-viscosity type), with the increase of viscosity, flow meters to measure off the assembly line value improved the scope of the degree of narrowing poor linearity. 11) fluid properties (density, viscosity) on the instrument characteristics have a greater impact. Gas flow meter is susceptible to the density of liquid flow meter is sensitive to changes in viscosity. Closely related to the density and viscosity with temperature, pressure, temperature in the field, the pressure fluctuations are inevitable, according to their degree of accuracy the impact to take compensatory measures in order to maintain a high measurement accuracy. 12) by the flow meter to flow velocity distribution distortion and rotating flow, the sensor on the downstream side of the need to set up a long straight pipe, such as the installation space is limited, can be installed in order to shorten the length of straight pipe flow regulator (rectifier) . 13) is not suitable for the measurement of pulsating flow and mixed flow. 14) The cleanliness of the measured medium, require a higher limit its field of application, although the filter can be installed in order to adapt to the dirty media, but also to bring pressure loss increases to maintain the amount of increase in side effects. Please contact Sales Manager: Zeng ultra- Sales Hotline: 18637313237 15517300086 Tel :0373-2,677,766 Fax :0373-2,678,899 QQ: 83,380,304 Postal Code: 453 700 Ground Address: Grace Avenue, Xinxiang City, Henan Province, the western part of high-Bay northbound Name Said: Henan Airlines Traffic Instrument Co., Ltd. Main Page: http://www.hnxhyb.com / |
Admin>>>
You are the 21150 visitor
Copyright © GuangDong ICP No. 10089450, Singapore Airlines Traffic Instrument Co., Ltd., Henan Province All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 21150 visitor
Copyright © GuangDong ICP No. 10089450, Singapore Airlines Traffic Instrument Co., Ltd., Henan Province All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility